A logger may remain at a property or meter chamber after the investigator leaves, so its identity, boundary and configuration need a clear receipt. Leak detection in Brentford should record installation and removal as two controlled events, protecting data quality, equipment custody and the site handover.

Identify the device and measured boundary

Record make, model, serial, sensor or pulse connection, meter or test point, units and sampling interval. Photograph the device and wider location. Confirm the meter serial or circuit reference rather than relying on proximity.

State what the logger can and cannot measure. Flow logging may show demand patterns but not the defect location; pressure logging applies to the connected boundary and operating conditions.

Record installation conditions

Capture date, time reference, clock offset, initial reading, battery or status and person installing. Note valve states, users, automatic equipment and any site condition that affects interpretation.

Agree access, security, weather protection and who must not move the device. Keep door codes or sensitive site information outside the general technical report.

Control custody and changes

Give the client a receipt with equipment reference, location, planned retrieval and contact. If someone resets, moves or observes a fault, log the time and action. Do not hide gaps or substitute an unrecorded device.

Where the logger sits on communal or business equipment, follow site permits and notify affected managers. The equipment must not obstruct safe access or encourage untrained users to operate controls.

Close at retrieval

Photograph the device before removal, record final reading, clock drift, status, data range and any damage. Confirm the site and controls were left as agreed. Give a receipt acknowledging recovery.

Preserve raw export and create a separate working analysis. Link gaps, time corrections and events to the report. This provides an auditable dataset rather than an unexplained graph detached from the device and property. Add an installation-and-removal comparison showing clock offset, battery status, seal or mounting condition, initial and final readings and any intervention. If the logger is not found where installed, stop the analysis until its identity and custody are resolved. Record the recipient of the data and the retention review. A complete receipt makes both equipment and evidence accountable without implying that the client certified the logger configuration.