A test may stop because service is needed, equipment fails, conditions change or a safety concern appears. After leak detection in Didcot, the report should retain the planned duration, actual duration and reason. An early result must not be labelled a full pass simply because no escape appeared before interruption.
Preserve the test plan
Record the intended boundary, method, pressure or operating state, duration and acceptance basis before starting. This provides the comparison when interruption occurs.
Log readings and observations continuously enough to preserve the usable portion. Do not delete the run merely because it is incomplete.
Classify the interruption
State who stopped the test and why: occupancy need, equipment issue, unsafe condition or unexpected system behaviour. The reason affects whether repetition is valid.
Record any intervention such as repressurising, opening an outlet or changing a valve. These actions end comparability unless incorporated deliberately.
Decide what the partial run supports
A short stable period may support immediate workmanship observations without satisfying the planned verification. State the limited conclusion and remaining risk.
If safe and useful, repeat under a new identifier with comparable starting conditions. Preserve both runs and explain differences.
Close or keep open honestly
Assign any further monitoring or re-test with owner and date. Do not allow reinstatement to hide a verification action that still requires access.
For leak detection in Didcot, transparent interruption records prevent schedule pressure from turning incomplete evidence into certainty. The final repair status should match the test actually completed, not the one originally intended.
Where the property must regain service, agree whether a later monitoring period can complete verification without recreating the original test. Record the system state at interruption and after restoration. A repeat on another day should not reuse the same identifier or omit changes in temperature, occupancy and equipment. If reinstatement cannot wait, preserve access photographs and explain the evidential consequence before closure. The decision-maker can then weigh a repeat test, monitoring or accepted limitation rather than receiving an unsupported full-pass statement. State whether the original acceptance criterion was met, partly assessed or not assessed. Record the reason in the completion certificate or handover summary as well.