A symptom that appears warm or follows hot-water use does not prove a hot distribution pipe is leaking. Heat can travel, and water from other sources can be warmed by its surroundings. A defined boundary prevents the investigation from merging domestic hot water, heating and cold feed systems.
Name each system and control
Sketch the heat source, cylinder where present, cold feed, hot distribution, secondary return and nearby heating circuits. Label visible valves and test points, and mark inferred concealed routes. Record appliance type and obtain competent help before operating unfamiliar equipment or controls.
State the symptom and operating condition: after one outlet, during reheating, continuously or only at certain times. Preserve direct temperatures or readings with method and location, but do not treat a warm surface as source identification.
Test one proposition at a time
Agree which boundary can be isolated or monitored safely and what other services that action affects. Record start state, duration, outlets kept unused and any pressure or meter readings. A result on the cold inlet may answer a different question from a test on a sealed heating circuit.
Do not close safety valves, override controls or change system pressure to provoke leakage. Boiler, unvented cylinder and specialist heating work requires the right competence. If the evidence instead points to drainage or an appliance, make a documented referral.
Report limits and the repair decision
Show which branch was supported, excluded under test conditions or left unresolved. Intermittent draw-off or inaccessible circulation may justify logging rather than destructive access. Mark the proposed access zone and explain the confidence without guaranteeing an exact joint.
After exposure, confirm pipe identity before repair and update the sketch. Record the repair and test under appropriate operating conditions, then state who returned the system to service. This lets a later reader distinguish a hot-water finding from heating or cold-supply assumptions that were never tested. Give each circuit a stable name in photographs, readings and the final invoice. If a valve passes water or a return loop changes the boundary, record that complication rather than forcing the data into the original sketch. Any restriction on hot-water use should name the responsible contact and review time so occupants are not left to experiment with controls. Add the temperatures and operating duration used for the final check, with any manufacturer limitation that affected interpretation.