An underfloor-heating manifold can contain several loops, valves, actuators and gauges whose labels no longer match rooms. Leak detection in Richmond should create a photo schedule before any control is moved, then link each test and repair to the same verified circuit name.
Photograph the untouched manifold
Take orientation, full manifold and close images of every position, label, gauge and connection. Record the heat source and operating state. Do not rotate valves or actuators merely to improve visibility.
Give each position a stable identifier based on manifold and port, then cross-reference the room label as provisional. Old labels may be wrong after alterations.
Record each operating change
For isolation or testing, note initial and final valve positions, pressure, temperature, time and competent person. Photograph changed states. Boiler, sealed-system and commissioning work needs appropriate competence; never override safety controls.
If a loop cannot be isolated cleanly, mark the result as a shared boundary. A pressure change on the manifold does not automatically identify one floor defect.
Link evidence to the right loop
Cite the port identifier on thermal images, pressure logs and room maps. Record elapsed heating or cooling time. Surface temperature patterns show conditions, not exact depth or defect identity.
Preserve contradictory results and inactive loops. The schedule should make it possible to see which circuit was actually operating when an indication appeared.
Update after repair
Confirm the exposed pipe and port before alteration. Add the repair, cold and operating tests, refill or balancing work and return-to-service status. Keep earlier labels in the revision history.
Give the owner the final photo schedule and circuit drawing. This prevents future work from repeating uncertain loop names and keeps a local repair from being treated as certification of every underfloor circuit. Include a port-by-port status table: active, inactive, isolated, tested, repaired or not assessed. Note the thermostat or controller term used by occupants. If any label remains uncertain, assign a further identification action rather than choosing a room name because it seems likely from position. Record the operating conditions and elapsed time for each photographed reading, plus any actuator that failed to respond or was overridden by an authorised specialist.