A copied number can look credible even when its unit is wrong. During leak detection in St Albans, confusing bar with another pressure unit, litres with cubic metres, or one moisture scale with another can change the apparent result. The correction must revisit calculations and decisions, not simply replace the label.
Identify the source value
Return to the instrument display, raw export or contemporaneous log and record the actual unit. Do not calculate backwards from the report if the source is available.
Check equipment settings and whether conversion occurred automatically. Preserve the original file and the erroneous report version.
Trace every affected use
Review charts, thresholds, calculations, quotations and conclusions that relied on the value. A unit typo may be cosmetic or may reverse a decision.
Notify recipients whose action could be affected and pause dependent work where appropriate. Do not wait for the final report cycle if access or repair is imminent.
Issue a controlled correction
Show the old entry, correct entry, calculation and effect on the conclusion. Give the notice a date and revision and link it to the report.
Avoid rewriting unaffected measurements. A narrow correction is easier to audit than a new document with unexplained wording changes.
Prevent recurrence
Use unit fields, validation and peer review for decisive measurements. Keep scales and units visible in images and tables.
For leak detection in St Albans, a transparent unit correction preserves trust and may prevent unnecessary access. The technical conclusion should reflect the corrected evidence, while the history shows exactly how the error was found and resolved.
Recalculate graphs and derived rates from the source value rather than applying a visual label change. Ask a second reviewer to check the conversion where it controls repair or claim decisions. If the corrected number remains within the same interpretation, say so; a harmless typo still deserves correction but need not create a false change in advice. Store the conversion formula, rounding and source unit with the test record. Future comparisons must use the corrected unit and should not combine historic figures until their scales have been verified. Update every chart caption and summary table. Check quoted thresholds and axis labels before reissuing the report.