Water at or near a downlight creates an electrical question as well as a source question. The occupant should avoid contact and seek competent assistance. A leak investigator can record the wetting event and plumbing evidence but cannot declare the circuit safe without appropriate electrical competence.
Record without approaching the hazard
Keep people away and follow advice from a competent electrician or emergency service. Do not touch the fitting, switch it, remove it or stand beneath unsafe ceiling material for a photograph. Record water timing, appearance and location from a safe reference.
Note who isolated electricity, at which labelled control and when. Do not infer isolation from a switch position. Record any plumbing isolation or temporary containment separately.
Coordinate the two investigations
Give the electrician a room plan, affected fitting, moisture area, suspected plumbing system and access already made. Mark concealed routes as inferred. The electrician decides inspection, testing and re-energisation; the plumber controls water work within competence.
If ceiling access is required, agree who checks services, structure and asbestos information. Do not enlarge around the fitting solely to improve leak visibility. Set a stop point and responsible site controller.
Close both handovers
The leak record should state source, repair and water-system verification. The electrical record should state its own findings and controls. Name the person who may restore each service and give occupants clear restrictions.
Before reinstatement, confirm required drying, electrical and plumbing actions are complete. Keep dated versions and photographs. This prevents a repaired pipe from being mistaken for electrical clearance and ensures later decoration does not conceal an unresolved safety action. Add a handover table with water source status, electrical status, ceiling condition, temporary protection and responsible person. Every status should cite its professional record and time. If the light remains isolated, label the restriction and tell occupants which controls must not be used. When the leak location changes, issue the electrician an updated marked plan and record whether further assessment is required before re-energisation. Keep the final downlight and ceiling photographs after restoration and link them to both professional handovers. Record who removed each warning label and the evidence authorising removal.