Leak detection in Walton-on-Thames: can logger clock drift change the conclusion?

Exact Source · 5 November 2026 · 2 min read

A logger may record regular samples accurately while its internal clock slowly diverges from the event diary or building controls. In Walton-on-Thames leak detection, clock drift can make a flow peak appear before or after the appliance, heating or isolation event used to explain it.

Check the clock at installation

Photograph device, serial, display or configuration and compare its time with a stated reference. Record the offset, timezone and sampling interval. Do not reset the clock without preserving the original relationship to earlier data.

Confirm the logger’s measured boundary, units and sensor or pulse arrangement. A perfectly timed dataset on the wrong meter or pressure point is not useful evidence.

Maintain an event reference

Use the same reference for occupant notes, valve actions, controller cycles and photographs. Mark estimates as estimates. If an event source uses another clock, record that offset too.

Check the logger during long monitoring where practical. Battery changes, restarts and daylight-saving changes can produce gaps or jumps that should remain visible.

Measure drift at retrieval

Compare the device clock again and calculate whether the difference changed linearly or through a sudden reset. Preserve raw timestamps and create a corrected analysis copy with the method recorded.

Do not claim second-level alignment when the sample interval is longer or the event time approximate. The conclusion should reflect the weakest time precision in the comparison.

Reassess event associations

Test whether flow or pressure patterns still align after correction. Keep associations that weaken or disappear. A new timing relationship may point to another user, an automatic process or a different leak proposition.

The final report should include installation and retrieval checks, data gaps and correction notes. This makes logger evidence reviewable and prevents a clock artefact from driving unnecessary access. Show the original timestamp, corrected timestamp and applied offset for key events, with the calculation method. If drift was nonlinear or the device reset, divide the analysis into defensible periods instead of applying one blanket correction. Preserve the raw export and any software version used to create the working graph.