Woking · Leak detection guidance

Leak detection in Woking: how should observations, recollections and inferences be separated?

Exact Source · 16 November 2026 · 3 min read

A useful leak report contains more than readings. It may include what the investigator saw, what an occupant remembers and what those facts are thought to mean. If those elements are blended into one narrative, a later reader can mistake a recollection for a measurement or an inference for proof. Leak detection in Woking benefits from making the status of each statement visible.

Give direct observations their conditions

‘The meter moved’ is incomplete without the time, observation period and isolation conditions. ‘The wall was damp’ is stronger when the report identifies the face of the wall, the instrument or visual sign used and relevant comparison points. A direct observation should be reproducible enough for another competent person to understand what was actually checked.

Instrument output is not automatically a conclusion. A thermal pattern, moisture indication or sound response belongs in the evidence section with its setting and limitations. The interpretation comes afterwards.

Attribute the household account

Occupants often provide essential timing: when a stain first appeared, whether boiler pressure drops after heating, or which appliance was used before water became visible. Record that information as reported, preferably with the date it was given. Do not add certainty the speaker did not claim.

Conflicting accounts can both be relevant. Rather than selecting one, the report may say that the onset date is disputed and explain how this affects the investigation. ICO accuracy guidance recommends keeping the source and status of information clear and distinguishing opinion from fact—a sound discipline for technical records too.

Show the reasoning between evidence and conclusion

An inference should identify the facts that support it and any plausible alternatives. For example, a cool area aligned with pipework may justify targeted testing, but it does not alone prove an active escape. If a controlled pressure test and meter test point the same way, the combined case can be described more strongly.

The report should also say what would change the interpretation. Access revealing a sound pipe, drying data inconsistent with continued leakage or a repeat test under better isolation may all require revision. The limitations of thermal evidence are explored at https://exactsource.co.uk/advice/thermal-camera-limitations/.

Write the decision in proportion to confidence

The conclusion should match the evidence: confirmed visible defect, probable concealed leak zone, unresolved loss or no active leak demonstrated during the visit. These are different outcomes. Each can still support a practical next step, such as repair, limited access, monitoring or a repeat test under stated conditions.

When someone searches ‘cannot find my leak’, they need clarity about what is known and what remains uncertain. Labelling observations, recollections and inferences gives the repair contractor a usable brief and prevents later decisions from resting on a sentence that was never intended as proof.